Why Aberystwyth needs real PTV data.
Hospitals, care homes and universities in and around Aberystwyth operate 24/7 with mixed footwear, wet-cleaning regimes and vulnerable users. A PTV of 36+ in both wet and dry states is the baseline — anything less is a CQC, HSE or insurance conversation waiting to happen.
Trusts and universities across Aberystwyth use pendulum testing not just after incidents but as a scheduled part of planned-preventative maintenance. Early warning on a declining PTV prevents both claims and capital replacement.
Typical test zones in Aberystwyth
- Ward corridors
- Wet rooms
- Canteens
- Atrium floors
- University common areas
- Lab zones
Pendulum testing. Not opinion.
The pendulum method — defined in BS 7976 and BS EN 16165, and referenced throughout HSE guidance — is the only test HSE considers reliable on wet or contaminated floors. A rubber slider swings from a fixed height and drags across the test surface; energy lost to friction is recorded as a Pendulum Test Value (PTV) on a scale of 0 to 150.
HSE classifies any PTV below 25 as a high slip potential. 25–35 is moderate. A PTV of 36 or above, measured wet and dry with the correct reference slider, is the benchmark for a floor considered safe under normal use. Every report we produce in Aberystwyth is issued under our UKAS ISO/IEC 17025 accreditation — the method, the technician and the equipment are all independently audited.
Slip testing in Aberystwyth
Fixed quote within one working day. UKAS-accredited report in five.
Request a Quote →